Data Center Power Quality and Assurance (Key Considerations for Financial Institutions) 
  If the data center of a financial service provider goes down due to a power glitch, the impact is significant – there’s potential damage to equipment, applications and systems. 

ECO mode VS online double-conversion 
  Choosing a UPS involves many quality-based considerations. This paper examines those considerations with the aim of choosing the optimal UPS for the job.  

OVP – Over Voltage Protection Unit Release 
  The OVP is an electronic unit that protects critical loads from damage caused by common types of 

The Benefits of Modularity 
  The modular UPS first entered the market approximately a decade ago. One may ask, why only then? What aroused consumers 

Three-Phase Transformers 
  INTRODUCTION TO TRANSFORMERS A transformer is a device that transfers electrical energy from one circuit to another through inductively coupled 

Telecom Rectifier Uninterrupted Power Supply (UPS) 
  Telecom RectifierTelecom rectifier power supplies are dc power supplies. They supply power during normal operation and are backed-up with uninterrupted power supplies (UPS) during power failure. 


DC/DC Converter

This DC-DC converter module converts a nominal 48V (42V-61.5V) into 24V (25A maximum) accurate voltage at the output.
The unit comes with the option to set several similar modules in parallelTelecom Rectifier in order to gain more power and redundant operation (N+1).
Output voltage is set by a single trimmer-potentiometer, using a small screwdriver.
Each DC to DC Power Converter is protected against input low/high voltage, output over-voltage, over temperature and output over-load.
A low-voltage-disconnect (LVD) is included at the input stage to protect the potential battery at the input from being deeply discharged.
Galvanic isolation between input and output. There are four leds in the front panel which indicate the load level.
The DC Transformers are protected against input low/high voltage, output over-voltage, over temperature and output overload or shorting (short circuit). Each unit is Hot-Swap, 3 units in a 1U, 19″ shelf (total 1,800W per shelf).

DC/DC Converter

INPUT Single Dc-Dc 48-24 Module
Voltage range 42÷ 61.5VDC
Current 17A (max)
Efficiency >88%p
Protection 47÷63 Hz
Low Voltage >60 sec
Restart operation 0.99
Voltage 24VDC
Current limit 25A (folds back to 9A at shortcircuit)
Voltage adjustment ±5%
Voltage regulation ±1%
Ripple 50mVrms
Protection Over load, output OVP, Over-temperature
Display 4 LED bar-graph display the load level
Parallel operation Active current-sharing
Ambient temperature -10÷50°C
Humidity 0-95 %
Dimensions (mm) 146 (W); 44 (H); 260 (D) 0.8
Weight (Kg)  
Withstand voltage
Input – Output: 1500VDC
Input – chassis: 1500VDC
Output – chassis: 1500VDC
Cooling Forced, fan speed control
Safety IEC950, EN60950
EN55022, EN6100-4-2
2,3,4,5,6,11 ,EN61000-3-2
EN6100-3-2, EN61000-3-3

Gamatronic Electronic Industries Ltd.
Uninterruptible power supply 10KVA | Modular UPS System | Battery backup power | UPS Online | Data center UPS | UPS universal power supply | Electric UPS | UPS 60kva | UPS 80kva | Uninterruptible power supply 250KVA | Uninterruptible power supply systems | Uninterruptible power supplies ups | Marine ups | Uninterruptible power systems | Three phase ups | Industrial uninterruptible power supply | Battery backup power supply | 