Distributors Login Quick Enquiry Find a Reseller Technical Support
Subscribe to GamaNews:
 
Subscribe
Follow us on:
Power System - Power Supply 2012
Power System 2012
48V/6400A, 1 phase modules 48V/50A,
24V/100A and 3 phase modules 48V/100A


The PS 2012 can house up to 64 hot-plugged rectifiers, an LVD device, AC and DC distribution panels, optional DC/AC inverters and DC/DC converters — all managed and controlled by a sophisticated system controller, the SC 2012 NET.

Features
  • Up to 64 parallel hot-plugged rectifiers
  • One- or three-phase input configuration
  • Low voltage disconnect device (LVD) for battery protection (option for 2 LVDs)
  • High-performance system controller, SC 2012 NET, used to measure, monitor, and control voltages, currents, temperature, battery parameters, and other data
  • Temperature compensation for extended battery life
  • Up to two battery sets handled in one system
  • Automatic and pre-programmed battery test algorithm
  • Automatic and pre-programmed equalize charging mode
  • AC and DC distribution panels, flexible in accommodating user requirements
  • Intelligent digital active current sharing among rectifiers
  • Flexible user-defined signaling of dry contacts
  • Comprehensive remote control and monitoring software: GeMSi
  • RS232 and/or TCP/IP communication
System Controller 2012 NET
  • 24 user-definable digital inputs
  • 22 user-definable digital outputs
  • Four galvanic-isolated 10-bit resolution voltmeters
  • Up to four 10-bit resolution ampere meters
  • 24 indicator LEDs on the front panel
  • Control of up to 64 rectifiers
  • Control of up to 20 additional DC/DC converters
  • Large 4x40 character LCD with back light
  • Numeric keypad on panel
  • Control of LVD(s)
  • Periodic or manual battery check
  • DC voltage compensation according to battery temperature
  • Three temperature sensors for reliable measurement
  • Audible alarm
  • Calibration by software (all-digital, no analog potentiometers) of AC and DC currents and voltages measured by the controller
  • Real-Time-Clock (RTC) with backup
  • 256 events log and data log (statistic values)
  • Graphic user interface (GUI)
  • RS232 and / or SNMP (PPP-10BASET) and TCP/IP communication
Measurements and Indications
  • DC voltage
  • Load current
  • Battery current(s)
  • Rectifiers currents
  • AC voltage(s), current(s), and frequency
  • Status of input, output, LVD, rectifiers, battery, system breakers
  • Battery temperature
  • Dry-contact signalization, user-definable (14 alarms)
Control
  • Battery test
  • DC voltage setting (EQUALIZE or FLOAT charge modes)
  • LVD threshold setting (connect, disconnect)
  • Rectifier activation/shutdown (up to 48 rectifiers in one power system)
Download PDF Brochure:
Catalogue

open

X